This is a used Mullard M8162, this is a special quality  ECC81, identical to the CV4024 and the 12AT7WA, tested with good results, see below.

Valve: M8162 / ECC81
Type: double triode
Make: Mullard, Mitcham
Factory code: R1C2
Sold as: used
 
Results:

Test conditions: Vf = 6.3  Va =250V  Vg = -2.0V
Tested for heater continuity and electrode insulation 
Design Actual
A1 (mA) 10.0 9.4
gm1 (mA/V) 5.5 6.2
A2 (mA) 10.0 8.6
gm2 (mA/V) 5.5 6.2

Tests carried out on an AVO VCM Mk3, design figures taken from AVO valve data manual.